Battery Capacity Calculator & kWh to Ah Conversion Tool

Size your 48V / 51.2V LiFePO4 battery system in seconds. Convert kWh to Ah, estimate runtime and backup time, and right-size your energy storage for home, commercial and industrial loads.

Free Tool

Battery Capacity Calculator

Enter your battery voltage, capacity and load. Total energy, usable energy, runtime and required capacity update live as you type.

1 · Battery & Load Inputs

2 · Results

Total Energy
—
Voltage × Capacity ÷ 1,000
Usable Energy
—
Total × DoD
Runtime at Load
—
Usable energy ÷ load
Required Capacity
—
For target time (Ah)

DoD limits how much of the battery you should use each cycle; 80% is the recommended value for LiFePO4. Actual usable capacity is affected by temperature, discharge rate and battery age — always keep a safety margin in real deployments.

Quick Start — dawnice Product Line

Note: dawnice "48V" series batteries use a 51.2V nominal voltage (16-cell LiFePO4 architecture), which is why a 100Ah pack stores 5.12kWh rather than 4.8kWh. Each preset fills the calculator with a realistic load for its use case.

Unit Converter

kWh · Ah · Watts · Amps Converter

Four conversion tools in one. Enter any two values in a tab and the third is calculated automatically.

Ah = kWh × 1,000 ÷ V · kWh = V × Ah ÷ 1,000. Leave the field you want computed empty (or edit any two values).
W = V × A · A = W ÷ V · V = W ÷ A.
kWh = kW × time (h) · kW = kWh ÷ time · time = kWh ÷ kW.
Ah = Wh ÷ V · Wh = V × Ah · V = Wh ÷ Ah.
Sizing Guide

How to Size Your LiFePO4 Battery

Sizing a battery comes down to one simple relationship: energy equals voltage times capacity. A 48V, 200Ah LiFePO4 battery stores 48 × 200 = 9,600Wh, or 9.6kWh of total energy. That figure tells you how much electricity the battery holds — but it is not the full amount you should safely use.

LiFePO4 chemistry is typically rated to about 80% depth of discharge (DoD). Using 80% of a 9.6kWh pack gives you 7.68kWh of usable energy. We recommend staying inside this limit to protect cycle life. Actual usable capacity is also affected by temperature, discharge rate and battery age, so keep a safety margin on top.

Next, match the battery to your load. Divide usable energy by average load power to estimate runtime. A 7.68kWh usable pack running a 500W load lasts about 15.4 hours; running a 2,000W load, about 3.8 hours. If you know how long backup must last, work backwards: required capacity (Ah) = load (W) × target hours ÷ voltage ÷ DoD.

For commercial and industrial loads in the 1–10kW range, a 48V or 51.2V system is the practical choice. Higher voltage means lower current for the same power, so cabling is thinner, cheaper and safer — and you can parallel multiple batteries to scale capacity as the business grows.

If you operate in markets with unstable grids — such as parts of Africa, including Nigeria — plan for 8 to 12 hours of backup capacity per day. Size for the longest expected outage, not the average, and remember that peak loads usually exceed your average draw. Start with your daily load, add your outage target, and let the calculator above show you the numbers.

Why It Matters

Why Choose 48V / 51.2V Systems

Higher efficiency

Lower current means fewer resistive losses in cabling and connections, so more stored energy reaches your inverter and appliances.

Thinner, cheaper cabling

A 48V system carries the same power at roughly a quarter of the current of a 12V system, cutting cable gauge, connectors and installation cost.

Easy parallel expansion

Multiple 48V/51.2V packs connect in parallel to scale from a few kWh to tens or hundreds of kWh without redesigning the system.

Mainstream inverter compatibility

48V is the industry-standard input for leading hybrid inverters, solar controllers and chargers, simplifying procurement and spare parts.

Stable commercial performance

Built for daily B2B cycling with BMS protection, consistent voltage output and predictable service life for business-critical loads.

FAQ

Battery Calculator FAQ

How do I calculate the total energy of a LiFePO4 battery?
Multiply the battery voltage by its capacity in amp-hours and divide by 1,000: energy (kWh) = voltage (V) × capacity (Ah) ÷ 1,000. For example, a 48V 200Ah battery stores 48 × 200 ÷ 1,000 = 9.6kWh.
What depth of discharge (DoD) should I use for LiFePO4 batteries?
We recommend 80% DoD for LiFePO4. Staying inside this limit protects cycle life and leaves a safety margin. Actual usable capacity is also affected by temperature, discharge rate and battery age.
Why is my 48V 100Ah battery rated 5.12kWh instead of 4.8kWh?
A "48V" LiFePO4 battery is typically built with 16 cells at a nominal voltage of 51.2V, so 51.2V × 100Ah ÷ 1,000 = 5.12kWh. "48V" is an industry naming convention; the higher nominal voltage is what determines stored energy.
How long will my battery run my appliances?
Divide usable energy by load power: runtime (h) = usable energy (kWh) × 1,000 ÷ load (W). For example, 7.68kWh of usable energy running a 500W load lasts about 15.4 hours.
How do I convert kWh to Ah?
Divide kWh by voltage and multiply by 1,000: Ah = kWh × 1,000 ÷ voltage. For a 51.2V system, 5.12kWh equals 5.12 × 1,000 ÷ 51.2 = 100Ah.
How much backup capacity should I plan for in Nigeria or other grid-unstable markets?
For areas with frequent power cuts, such as parts of Africa including Nigeria, plan for 8–12 hours of backup per day. Estimate your average daily load in kWh, multiply by your target outage hours, and size the battery with an 80% DoD margin.